New methods of data calibration for high power-aperture lidar
Guan, Sai1; Yang, Guotao1; Chang, Qihai2; Cheng, Xuewu3; Yang, Yong3; Gong, Shaohua4; Wang, Jihong1; 北京8701信箱
Department空间天气学国家重点实验室
Source PublicationOPTICS EXPRESS
2013-03-25
Volume21Issue:6Pages:7768-7785
ISSN1094-4087
Language英语
AbstractFor high power-aperture lidar sounding of wide atmospheric dynamic ranges, as in middle-upper atmospheric probing, photomultiplier tubes' (PMT) pulse pile-up effects and signal-induced noise (SIN) complicates the extraction of information from lidar return signal, especially from metal layers' fluorescence signal. Pursuit for sophisticated description of metal layers' characteristics at far range (80~130km) with one PMT of high quantum efficiency (QE) and good SNR, contradicts the requirements for signals of wide linear dynamic range (i.e. from approximate 10(2) to 10(8) counts/s). In this article, Substantial improvements on experimental simulation of Lidar signals affected by PMT are reported to evaluate the PMTs' distortions in our High Power-Aperture Sodium LIDAR system. A new method for pile-up calibration is proposed by taking into account PMT and High Speed Data Acquisition Card as an Integrated Black-Box, as well as a new experimental method for identifying and removing SIN from the raw Lidar signals. Contradiction between the limited linear dynamic range of raw signal (55~80km) and requirements for wider acceptable linearity has been effectively solved, without complicating the current lidar system. Validity of these methods was demonstrated by applying calibrated data to retrieve atmospheric parameters (i.e. atmospheric density, temperature and sodium absolutely number density), in comparison with measurements of TIMED satellite and atmosphere model. Good agreements are obtained between results derived from calibrated signal and reference measurements where differences of atmosphere density, temperature are less than 5% in the stratosphere and less than 10K from 30km to mesosphere, respectively. Additionally, approximate 30% changes are shown in sodium concentration at its peak value. By means of the proposed methods to revert the true signal independent of detectors, authors approach a new balance between maintaining the linearity of adequate signal (20-110km) and guaranteeing good SNR (i.e. 10(4):1 around 90km) without debasing QE, in one single detecting channel. For the first time, PMT in photon-counting mode is independently applied to subtract reliable information of atmospheric parameters with wide acceptable linearity over an altitude range from stratosphere up to lower thermosphere (20-110km).; For high power-aperture lidar sounding of wide atmospheric dynamic ranges, as in middle-upper atmospheric probing, photomultiplier tubes' (PMT) pulse pile-up effects and signal-induced noise (SIN) complicates the extraction of information from lidar return signal, especially from metal layers' fluorescence signal. Pursuit for sophisticated description of metal layers' characteristics at far range (80 similar to 130km) with one PMT of high quantum efficiency (QE) and good SNR, contradicts the requirements for signals of wide linear dynamic range (i.e. from approximate 10(2) to 10(8) counts/s). In this article, Substantial improvements on experimental simulation of Lidar signals affected by PMT are reported to evaluate the PMTs' distortions in our High Power-Aperture Sodium LIDAR system. A new method for pile-up calibration is proposed by taking into account PMT and High Speed Data Acquisition Card as an Integrated Black-Box, as well as a new experimental method for identifying and removing SIN from the raw Lidar signals. Contradiction between the limited linear dynamic range of raw signal (55 similar to 80km) and requirements for wider acceptable linearity has been effectively solved, without complicating the current lidar system. Validity of these methods was demonstrated by applying calibrated data to retrieve atmospheric parameters (i.e. atmospheric density, temperature and sodium absolutely number density), in comparation with measurements of TIMED satellite and atmosphere model. Good agreements are obtained between results derived from calibrated signal and reference measurements where differences of atmosphere density, temperature are less than 5% in the stratosphere and less than 10K from 30km to mesosphere, respectively. Additionally, approximate 30% changes are shown in sodium concentration at its peak value. By means of the proposed methods to revert the true signal independent of detectors, authors approach a new balance between maintaining the linearity of adequate signal (20-110km) and guaranteeing good SNR (i.e. 10(4):1 around 90km) without debasing QE, in one single detecting channel. For the first time, PMT in photon-counting mode is independently applied to subtract reliable information of atmospheric parameters with wide acceptable linearity over an altitude range from stratosphere up to lower thermosphere (20-110km).
Indexed BySCI
Funding Project中国科学院空间科学与应用研究中心
Citation statistics
Document Type期刊论文
Identifierhttp://ir.nssc.ac.cn/handle/122/1548
Collection空间科学部
Corresponding Author北京8701信箱
Affiliation1.Chinese Acad Sci, Natl Space Sci Ctr, State Key Lab Space Weather, Beijing 100190, Peoples R China
2.Tibet Univ Nationalities, Xian 712082, Peoples R China
3.Chinese Acad Sci, Wuhan Inst Phys & Math, State Key Lab Magnet Resonance & Atom & Mol Phys, Wuhan 430071, Peoples R China
4.Hainan Normal Univ, Sch Phys & Elect Engn, Haikou 570000, Peoples R China
Recommended Citation
GB/T 7714
Guan, Sai,Yang, Guotao,Chang, Qihai,et al. New methods of data calibration for high power-aperture lidar[J]. OPTICS EXPRESS,2013,21(6):7768-7785.
APA Guan, Sai.,Yang, Guotao.,Chang, Qihai.,Cheng, Xuewu.,Yang, Yong.,...&北京8701信箱.(2013).New methods of data calibration for high power-aperture lidar.OPTICS EXPRESS,21(6),7768-7785.
MLA Guan, Sai,et al."New methods of data calibration for high power-aperture lidar".OPTICS EXPRESS 21.6(2013):7768-7785.
Files in This Item:
File Name/Size DocType Version Access License
20132167768.pdf(3580KB) 开放获取CC BY-NC-SAApplication Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Guan, Sai]'s Articles
[Yang, Guotao]'s Articles
[Chang, Qihai]'s Articles
Baidu academic
Similar articles in Baidu academic
[Guan, Sai]'s Articles
[Yang, Guotao]'s Articles
[Chang, Qihai]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Guan, Sai]'s Articles
[Yang, Guotao]'s Articles
[Chang, Qihai]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.