NSSC OpenIR  > 微波遥感部
FY-3B卫星微波湿度计热真空定标方法和结果分析
Alternative TitleThermal/vacuum calibration of microwave humidity sounder on FY-3B satellite
王振占; 张升伟; 李靖; 北京8701信箱
Department国家863计划微波遥感技术实验室
Source Publication中国工程科学
2013
Volume15Issue:10Pages:33-46
ISSN1009-1742
Language中文
Keyword风云三号卫星 微波湿度计 发射前定标 热真空定标
Abstract本文论述了风云三号卫星B星微波湿度计(MWHS-3B)发射前热真空定标的原理和方法,建立了各种定标误差的修正算法,获得了MWHS-3B的系统线性度、观测不同目标的灵敏度和最终定标精度等关键技术指标。这些参数已经用于MWHS-3B在轨数据的处理。
Other AbstractThe principle and methods on thermal/vacuum (T/V) testing of microwave humidity sounder (MWHS) on FY-3B satellite were described; correction algorithms on calibration errors were developed, and some main specifications of MWHS-3B, such as linearity, sensitivity and calibration precision, were obtained. The parameters derived from the T/V testing had been used in in-orbit data processing to produce brightness temperature products in FY-3B ground system.
Funding Project中国科学院空间科学与应用研究中心
Document Type期刊论文
Identifierhttp://ir.nssc.ac.cn/handle/122/2084
Collection微波遥感部
Corresponding Author北京8701信箱
Recommended Citation
GB/T 7714
王振占,张升伟,李靖,等. FY-3B卫星微波湿度计热真空定标方法和结果分析[J]. 中国工程科学,2013,15(10):33-46.
APA 王振占,张升伟,李靖,&北京8701信箱.(2013).FY-3B卫星微波湿度计热真空定标方法和结果分析.中国工程科学,15(10),33-46.
MLA 王振占,et al."FY-3B卫星微波湿度计热真空定标方法和结果分析".中国工程科学 15.10(2013):33-46.
Files in This Item:
File Name/Size DocType Version Access License
2013151033.pdf(2897KB) 开放获取CC BY-NC-SAApplication Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[王振占]'s Articles
[张升伟]'s Articles
[李靖]'s Articles
Baidu academic
Similar articles in Baidu academic
[王振占]'s Articles
[张升伟]'s Articles
[李靖]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[王振占]'s Articles
[张升伟]'s Articles
[李靖]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.