NSSC OpenIR  > 空间环境部
Study on the main performances of interferometric radiometers with a rotating array
Yin, Honggang; Lan, Ailan; Zhang, Shengwei
Department微波遥感部
Source PublicationProceedings of SPIE - The International Society for Optical Engineering
2014
Language英语
ISSN0277-786X
ISBN9781628413311
AbstractWhen observing unchanging targets or slow-changing targets, a rotating array can be used instead of a stationary array in an interferometric radiometer to reduce the complexity and the cost. The configuration of a stationary array determines its coverage in spatial frequency domain. But for a rotating array, the baselines were distributing on a series of concentric circles with radiuses of the baseline lengths, no matter what its configuration was. According to the characteristics of the distribution of the baselines, the expressions of system sensitivity and spatial resolution of a rotating interferometric radiometer were deduced in thwas paper. For a rotating interferometric radiometer with big synthetic aperture, like the Geostationary Interferometric Microwave Sounding (GIMS) prototype, it was very difficult to find a suitable calibration source to measure the system sensitivity. Therefore, the system sensitivity of the GIMS prototype was estimated based on the sensitivity of all channels by the sensitivity formula. Since the array factor of an interferometric radiometer was the pulse response of a point target, the spatial resolution of the GIMS prototype obtained by imaging an artificial quasi point target was used to demonstrate the formula in this paper, and the results were nearly identical. In addition, some different window functions were used to weight visibility samples of the prototype, and their effects on the sensitivity and the spatial resolution were analyzed. The principle of selecting the weighted window was described at the end. © 2014 SPIE.
Conference NameEarth Observing Missions and Sensors: Development, Implementation, and Characterization III
Conference DateOctober 13, 2014 - October 15, 2014
Conference PlaceBeijing, China
Indexed ByEI
Document Type会议论文
Identifierhttp://ir.nssc.ac.cn/handle/122/4351
Collection空间环境部
Recommended Citation
GB/T 7714
Yin, Honggang,Lan, Ailan,Zhang, Shengwei. Study on the main performances of interferometric radiometers with a rotating array[C]:SPIE,2014.
Files in This Item:
File Name/Size DocType Version Access License
201492641K.pdf(327KB) 开放获取CC BY-NC-SAApplication Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Yin, Honggang]'s Articles
[Lan, Ailan]'s Articles
[Zhang, Shengwei]'s Articles
Baidu academic
Similar articles in Baidu academic
[Yin, Honggang]'s Articles
[Lan, Ailan]'s Articles
[Zhang, Shengwei]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Yin, Honggang]'s Articles
[Lan, Ailan]'s Articles
[Zhang, Shengwei]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.