像素位置偏差对质心定位精度的影响
Alternative TitlePixel displacement effects on centroid position accuracy
曹阳; 李保权; 李海涛; 桑鹏
Department空间技术部
Source Publication红外与激光工程
2016
Volume45Issue:12Pages:1217007
ISSN1007-2276
Language中文
Keyword质心定位精度 微型星敏感器 像素位置偏差 外差式激光干涉装置
Abstract为提高微型星敏感器的质心定位精度,提出了一种利用外差式激光干涉装置标定图像传感器像素位置偏差的方法,并就像素位置偏差对星点像质心定位精度的影响进行了仿真研究。在噪声忽略不计的情况下,当像素位置偏差服从(-0.02,0.02)上的均匀分布时,补偿系统误差能够使星点定位精度从0.008 pixel提高到0.002 pixel。而如果加入服从N(0,5.52)的高斯白噪声,当像素位置偏差服从(-0.02,0.02)上的均匀分布时,补偿像素位置偏差能使定位精度从0.020 pixel提高到0.018 pixel;当像素位置偏差服从(-0.04,0.04)上的均匀分布时,补偿像素位置偏差能使定位精度从0.026 pixel提高到0.018 pixel,提高了31%。这说明标定像素位置偏差对提升质心定位精度有显著作用,为发展高精度微型星敏感器提供了一种新的技术手段。
Other AbstractIn order to improve the accuracy of centroiding for high precision miniature star tracker, a method to calibrate the imaging sensor pixel displacement using heterodyne laser interferometry was proposed. And the star position error due to imaging sensor pixel displacement was studied by simulation. The simulation results show that the accuracy of star position can be enhanced from 0.008 pixel to 0.002 pixel by compensating pixel displacement when pixel displacement obeys uniformly distributed over the interval(-0.02, 0.02) pixel. When the additive Gaussian noise in the star image has a normal distribution with mean 0 and standard deviation 5.5, if pixel displacement obeys uniformly distributed over the interval(-0.02, 0.02) pixel, the accuracy of star position can be enhanced from 0.020 pixel to 0.018 pixel after compensation; if pixel displacement obeys uniformly distributed over the interval(-0.04, 0.04) pixel, the accuracy of star position can be enhanced from 0.026 pixel to 0.018 pixel after compensation, which are 31% better than the accuracy without compensation. Simulation results show that calibrating pixel displacement which can significantly improves the star position accuracy can be used as a new method to develop high precision miniature star tracker.
Indexed ByCSCD
Citation statistics
Cited Times:1[CSCD]   [CSCD Record]
Document Type期刊论文
Identifierhttp://ir.nssc.ac.cn/handle/122/5820
Collection空间技术部
Recommended Citation
GB/T 7714
曹阳,李保权,李海涛,等. 像素位置偏差对质心定位精度的影响[J]. 红外与激光工程,2016,45(12):1217007.
APA 曹阳,李保权,李海涛,&桑鹏.(2016).像素位置偏差对质心定位精度的影响.红外与激光工程,45(12),1217007.
MLA 曹阳,et al."像素位置偏差对质心定位精度的影响".红外与激光工程 45.12(2016):1217007.
Files in This Item:
File Name/Size DocType Version Access License
201645121217007.pdf(929KB)期刊论文作者接受稿开放获取CC BY-NC-SAApplication Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[曹阳]'s Articles
[李保权]'s Articles
[李海涛]'s Articles
Baidu academic
Similar articles in Baidu academic
[曹阳]'s Articles
[李保权]'s Articles
[李海涛]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[曹阳]'s Articles
[李保权]'s Articles
[李海涛]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.