中国科学院国家空间科学中心机构知识库
Advanced  
NSSC OpenIR  > 微波遥感部  > 会议论文
题名: Simulation of actively polarimetric calibration source based on correlated noise signals by simulink
作者: Li, Jiaoyang; Wang, Zhenzhan
作者部门: 微波遥感部
会议名称: 2017 Progress In Electromagnetics Research Symposium - Fall, PIERS - FALL 2017
会议日期: November 19, 2017 - November 22, 2017
会议地点: Singapore, Singapore
会议录: Progress in Electromagnetics Research Symposium
出版日期: 2017
收录类别: EI
页码: 2344-2349
ISSN号: 1559-9450
ISBN号: 9781538612118
英文摘要: Fully polarimetric microwave radiometer can receive both the two orthogonal polarization components and their complex correlation components, which are defined as the third and fourth Stokes parameters, of the signals radiated from the detected target. In order to achieve the precisely quantitative remote sensing of fully polarimetric radiometer, an accurate calibration is necessary. For this purpose, a uniformly stable and accurate calibration source which is performed as the calibration standard is of vital importance. The traditional and commonly used blackbody calibration target can't radiate signals with polarized components. So it is significant to design an active calibration source to generate noise signals with full polarized components for fully polarimetric microwave radiometer calibration. With the full investigation into the pre-existing polarimetric calibration sources and their characteristics, this paper design a miniature and portable actively polarmetric calibration source. First of all, the design principles of the calibration source of fully polarized microwave radiometer based on correlated noise signals are elaborated. Secondly, MATLAB/Simulink is used to establish the simulation model of the calibration source. The reference signals generation module generates the original reference signals with full polarized components which can be controlled by program language. The original reference signals are converted to the signals with the designed frequency by the frequency modulation module. The noise voltage control module outputs the noise signals with different voltages which covered all the counts needed for polarimetric radiometer calibration within the voltage counts of cold and hot target. Finally, the power spectrum of each module of the simulation model is given. The results show a great consistency between the theoretical and simulated results. Thus, the feasibility of the designed calibration source for fully polarimetric microwave radiometer based on the program language controlled correlated noise signals is verified. Therefore, the functional block diagram of the real circuits of this calibration source based on the simulation is designed for the practical application. © 2018 Electromagnetics Academy. All rights reserved.
语种: 英语
内容类型: 会议论文
URI标识: http://ir.nssc.ac.cn/handle/122/6317
Appears in Collections:微波遥感部_会议论文

Files in This Item:
File Name/ File Size Content Type Version Access License
201708293528.pdf(186KB)会议论文--限制开放View 联系获取全文
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Li, Jiaoyang]'s Articles
[Wang, Zhenzhan]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Li, Jiaoyang]‘s Articles
[Wang, Zhenzhan]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit
文件名: 201708293528.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 
评注功能仅针对注册用户开放,请您登录
您对该条目有什么异议,请填写以下表单,管理员会尽快联系您。
内 容:
Email:  *
单位:
验证码:   刷新
您在IR的使用过程中有什么好的想法或者建议可以反馈给我们。
标 题:
 *
内 容:
Email:  *
验证码:   刷新

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2018  中国科学院国家空间科学中心 - Feedback
Powered by CSpace