Simulation of actively polarimetric calibration source based on correlated noise signals by simulink
Li, Jiaoyang; Wang, Zhenzhan
作者部门微波遥感部
会议录名称Progress in Electromagnetics Research Symposium
2017
页码2344-2349
语种英语
ISSN号1559-9450
ISBN号9781538612118
摘要Fully polarimetric microwave radiometer can receive both the two orthogonal polarization components and their complex correlation components, which are defined as the third and fourth Stokes parameters, of the signals radiated from the detected target. In order to achieve the precisely quantitative remote sensing of fully polarimetric radiometer, an accurate calibration is necessary. For this purpose, a uniformly stable and accurate calibration source which is performed as the calibration standard is of vital importance. The traditional and commonly used blackbody calibration target can't radiate signals with polarized components. So it is significant to design an active calibration source to generate noise signals with full polarized components for fully polarimetric microwave radiometer calibration. With the full investigation into the pre-existing polarimetric calibration sources and their characteristics, this paper design a miniature and portable actively polarmetric calibration source. First of all, the design principles of the calibration source of fully polarized microwave radiometer based on correlated noise signals are elaborated. Secondly, MATLAB/Simulink is used to establish the simulation model of the calibration source. The reference signals generation module generates the original reference signals with full polarized components which can be controlled by program language. The original reference signals are converted to the signals with the designed frequency by the frequency modulation module. The noise voltage control module outputs the noise signals with different voltages which covered all the counts needed for polarimetric radiometer calibration within the voltage counts of cold and hot target. Finally, the power spectrum of each module of the simulation model is given. The results show a great consistency between the theoretical and simulated results. Thus, the feasibility of the designed calibration source for fully polarimetric microwave radiometer based on the program language controlled correlated noise signals is verified. Therefore, the functional block diagram of the real circuits of this calibration source based on the simulation is designed for the practical application. © 2018 Electromagnetics Academy. All rights reserved.
会议名称2017 Progress In Electromagnetics Research Symposium - Fall, PIERS - FALL 2017
会议日期November 19, 2017 - November 22, 2017
会议地点Singapore, Singapore
收录类别EI
文献类型会议论文
条目标识符http://ir.nssc.ac.cn/handle/122/6317
专题微波遥感部
推荐引用方式
GB/T 7714
Li, Jiaoyang,Wang, Zhenzhan. Simulation of actively polarimetric calibration source based on correlated noise signals by simulink[C],2017:2344-2349.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
201708293528.pdf(186KB)会议论文 开放获取CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Li, Jiaoyang]的文章
[Wang, Zhenzhan]的文章
百度学术
百度学术中相似的文章
[Li, Jiaoyang]的文章
[Wang, Zhenzhan]的文章
必应学术
必应学术中相似的文章
[Li, Jiaoyang]的文章
[Wang, Zhenzhan]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。