NSSC OpenIR  > 微波遥感部
Simulation of actively polarimetric calibration source based on correlated noise signals by simulink
Li, Jiaoyang; Wang, Zhenzhan
Department微波遥感部
Source PublicationProgress in Electromagnetics Research Symposium
2017
Pages2344-2349
Language英语
ISSN1559-9450
ISBN9781538612118
AbstractFully polarimetric microwave radiometer can receive both the two orthogonal polarization components and their complex correlation components, which are defined as the third and fourth Stokes parameters, of the signals radiated from the detected target. In order to achieve the precisely quantitative remote sensing of fully polarimetric radiometer, an accurate calibration is necessary. For this purpose, a uniformly stable and accurate calibration source which is performed as the calibration standard is of vital importance. The traditional and commonly used blackbody calibration target can't radiate signals with polarized components. So it is significant to design an active calibration source to generate noise signals with full polarized components for fully polarimetric microwave radiometer calibration. With the full investigation into the pre-existing polarimetric calibration sources and their characteristics, this paper design a miniature and portable actively polarmetric calibration source. First of all, the design principles of the calibration source of fully polarized microwave radiometer based on correlated noise signals are elaborated. Secondly, MATLAB/Simulink is used to establish the simulation model of the calibration source. The reference signals generation module generates the original reference signals with full polarized components which can be controlled by program language. The original reference signals are converted to the signals with the designed frequency by the frequency modulation module. The noise voltage control module outputs the noise signals with different voltages which covered all the counts needed for polarimetric radiometer calibration within the voltage counts of cold and hot target. Finally, the power spectrum of each module of the simulation model is given. The results show a great consistency between the theoretical and simulated results. Thus, the feasibility of the designed calibration source for fully polarimetric microwave radiometer based on the program language controlled correlated noise signals is verified. Therefore, the functional block diagram of the real circuits of this calibration source based on the simulation is designed for the practical application. © 2018 Electromagnetics Academy. All rights reserved.
Conference Name2017 Progress In Electromagnetics Research Symposium - Fall, PIERS - FALL 2017
Conference DateNovember 19, 2017 - November 22, 2017
Conference PlaceSingapore, Singapore
Indexed ByEI
Document Type会议论文
Identifierhttp://ir.nssc.ac.cn/handle/122/6317
Collection微波遥感部
Recommended Citation
GB/T 7714
Li, Jiaoyang,Wang, Zhenzhan. Simulation of actively polarimetric calibration source based on correlated noise signals by simulink[C],2017:2344-2349.
Files in This Item:
File Name/Size DocType Version Access License
201708293528.pdf(186KB)会议论文 开放获取CC BY-NC-SAApplication Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Li, Jiaoyang]'s Articles
[Wang, Zhenzhan]'s Articles
Baidu academic
Similar articles in Baidu academic
[Li, Jiaoyang]'s Articles
[Wang, Zhenzhan]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Li, Jiaoyang]'s Articles
[Wang, Zhenzhan]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.